Effect of calculus and irrigator tip design on depth of subgingival irrigation
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 13 , Issue 3
May/June 1993

Pages 289-297


Effect of calculus and irrigator tip design on depth of subgingival irrigation

Larner/Greenstein


PMID: 8262724
DOI: 10.11607/prd.00.0052

This study addressed three factors that may affect the penetration of medicaments into periodontal pockets: calculus, ejection site pressure, and irrigator tip design. Ejection site pressure for the Max-I-Probe, the Viadent and Water-Pik tips were determined with a variant of Bernoullis’ equation. Depth of irrigant penetration was determined by delivering disclosing solution supragingivally and subgingivally. Following irrigation, assessed teeth were extracted and the percentage of pocket penetration by the dye was calculated. The Max-I-Probe and Viadent tips had significantly greater penetration than did the Water-Pik tip. Furthermore, calculus deposits reduced irrigation penetration in deep pockets (7 to 10 mm). Ejection site pressures of the three tips ranged from 0.10 to 4.80 psi. The ejection site pressure of the Max-I-Probe side-port delivery system was lower than that of the other two systems. Results indicated that subgingival calculus, irrigator tip design, and placement of the tip affect the depth to which drugs can be delivered subgingivally.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help